Terralux SR8 Install Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Éclairage Terralux SR8 Install. TERRALUX SR8 Install User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 3
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
TerraLUX Inc. Document P/N 025000085B
1-866-498-1564
www.terralux.com
MODELS: TLM-D08A-A12XXR
& TLM-D08A-B12XXR
ROUND LED RETROFIT KIT INSTALLATION
INSTRUCTIONS
WARNING - RISK OF FIRE OR ELECTRIC SHOCK. LED RETROFIT KIT INSTALLATION
REQUIRES KNOWLEDGE OF ELECTRICAL SYSTEMS. IF NOT QUALIFIED, DO NOT
ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN.
WARNING - RISK OF FIRE OR ELECTRIC SHOCK. INSTALL THIS KIT ONLY IN
LUMINAIRES THAT HAVE CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN
THE DRAWINGS “MIN. LAMP COMPARTMENT VOLUME 2200cm
3
(134 in
3
)
WARNING RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRE WIRING AND
ELECTRICAL PARTS MAY BE DAMAGED WHEN DRILLING FOR THE INSTALLATION OF
THIS LED RETROFIT KIT. CHECK ENCLOSED WIRING AND COMPONENTS.
WARNING TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING
TO EDGES OF SHEET METAL OR SHARP OBJECTS
DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR
ELECTRICAL COMPONENTS DURING KIT INSTALLATION.
SUITABLE FOR DAMP LOCATION.
CNL REQUIREMENT THIS MODULE HAS AN OUTPUT RATED AT 46VDC. THIS
OUTPUT COMPLIES WITH THE DEFINITION OF CLASS 2 PER THE CANADIAN
ELECTRICAL CODE. THIS OUTPUT CANNOT BE ACCESSIBLE BASED ON MAXIMUM
VOLTAGE RESTRICTIONS FOR CLASS 2 CIRCUITS IN THE CANADIAN ELECTRICAL
CODE. THE MODULE HAS ACCESSIBLE LED ARRAYS. THE LED ARRAYS OF THIS
MODULE AT THE END PRODUCT SHOULD BE IN COMPLIANCE WITH THIS
ACCESSIBILITY REQUIREMENT, EITHER BASED ON DESIGN OR BASED ON
MANUFACTURERS SPECIFICATIONS FOR IT’S USE IN RESTRICTED ACCESS AREAS.
THIS RETROFIT KIT IS INTENDED FOR INSTALLATION IN THE FOLLOWING TYPES OF LUMINAIRES:
INDOOR/OUTDOOR WALL SCONCE (INCANDESCENT OR BALLASTED FLUORESCENT)
INDOOR/OUTDOOR SURFACE MOUNTED CEILING FIXTURES(INCANDESCENT OR BALLASTED
FLUORESCENT)
INDOOR/OUTDOOR PENDANT MOUNTED LIGHT FIXTURES(INCANDESCENT OR BALLASTED
FLUORESCENT)
INCLUDED COMPONENTS
(1) RETROFIT KIT, MODELS TLM-D08A-A12XXR and TLM-D08A-B12XXR, INCLUDE:
o (1) WIRE HARNESS (1-WHITE,1-BLACK OR BLUE, 1-GREEN WIRE AND PLUG)
o (1) ROUND LED MOUNTING PLATE
o (1) LED DRIVER MODULE WITH SMALL CONNECTOR (8-WHITE WIRES)
(3) WIRE NUTS
(2) #8-32 x 1-1/4 IN. MACHINE SCREWS
(1) RUBBER GROMMET
(1) MOIST TOWELETTE
(1) 1/8IN x 1/8IN x 1/2IN STAMPED HICKEY SPACER
(1) 1/8-27 X 1/2IN THREADED NIPPLE
(2) 1/8-27 IPS HEX NUTS
USER REQUIRED TOOLS
#2 PHILLIPS SCREW DRIVER OR STRAIGHT BLADE
1/2in OPEN END BOX WRENCH OR PLIERS
DRILL WITH 3/8-INCH DIAMETER DRILL BIT
INSTALLATION STEPS (SURFACE MOUNT FIXTURE)
1. SHUT OFF POWER TO LIGHT FIXTURE AT THE BREAKER
2. REMOVE DIFFUSER/GLOBE FROM FIXTURE TO BE RETROFITTED, RETAIN HARDWARE.
3. DISCONNECT/REMOVE BULB(S) FROM FIXTURE. DISPOSE OF OR RECYCLE PROPERLY.
4. LOOSEN THE SCREWS THAT SECURE THE FIXTURE TO THE JUNCTION BOX (DO NOT REMOVE
SCREWS). IF THE FIXTURE IS ALSO SECURED BY A THREADED MOUNTING TUBE, REMOVE THE IPS
NUT IF NECESSARY.
5. SEPARATE FIXTURE FROM JUNCTION BOX TO EXPOSE FIXTURE WIRING.
6. DISCONNECT FIXTURE MAINS WIRING FROM JUNCTION BOX MAINS WIRES.
7. REMOVE BULB SOCKET(S), FIXTURE WIRE, BULB BRACKETS, AND/OR FLUORESCENT BALLAST FROM
FIXTURE.
8. ROUTE LED RETROFIT WIRE HARNESS (1-WHITE, 1-BLACK OR BLUE, 1-GREEN WIRE) WIRES
THROUGH WIRE OPENING IN FIXTURE. CONFIRM WIRES WILL NOT BE PINCHED BY ROUND LED
MOUNTING PLATE OR OTHER FIXTURE HARDWARE WHEN REASSEMBLED.
a. IF FIXTURE WIRE OPENING IS BLOCKED BY ROUND LED RETROFIT MOUNTING PLATE,
DRILL 3/8-INCH DIAMETER HOLE IN FIXTURE AND USE INCLUDED GROMMET.
Ceiling Fixture
Incandescent
Ceiling Fixture
Ballasted Fluorescent
Ceiling Fixture
Ballast and Wires Removed
Vue de la page 0
1 2 3

Résumé du contenu

Page 1 - MODELS: TLM-D08A-A12XXR

TerraLUX Inc. Document P/N 025000085B 1-866-498-1564 www.terralux.com MODELS: TLM-D08A

Page 2 - TUG ON

TerraLUX Inc. Document P/N 025000085B 1-866-498-1564 www.terralux.com 9. RE

Page 3 - 1-866-498-1564

TerraLUX Inc. Document P/N 025000085B 1-866-498-1564 www.terralux.com INSTALLATION STE

Commentaires sur ces manuels

Pas de commentaire